Motorline Professional LINCE 600 Double Swing Gate Opener Kit (Kit-Standard-2114)

Complete Kit for swing gate with two Motorline Professional LINCE 600 operators, ProfelmNet 2114 control board in a waterproof plastic box, a set of wired safety photocells, and two remote controls. 

  • Electromechanical operator with permanent lubrication
  • Maximum leaf width (with electric lock): up to 4.0 m
  • Maximum leaf width (without electric lock): up to 2.5 m
  • Maximum number of cycles per hour: up to 21 at 20 °C
  • Maximum number of cycles per day: up to 30
  • Piston stroke (useful): 60 cm  
  • Maximum force: 2300 N 
  • Single-phase motor. Motor operating voltage: 230 VAC
  • Motor absorbed power: 2X180 W
  • Motor winding thermal protection: 120 °C
  • Manual override with special hexagonal key
  • Warranty: 2 years

To order this product please call us at 210.555.0632 or buy it online from our eshop.

Contents of the LINCE 600 kit (Kit-Standard-2114)

Motorline Professional LINCE 600 swing gate operator kit (Kit-Standard-2114)
Our LINCE 600 (Kit-Standard-2114) kit includes:
  • LINCE 600 operator, 2 pcs
  • ProfelmNet PS-2114N control board installed in a waterproof box, 1 pc
  • 2 ProfelmNet PSD-36T remote controls at 433.92 MHz with 4 buttons
  • 1 set of wired photocells
  • All necessary accessories for the installation and operation of the mechanism (mounting bases and screws for the motor, capacitor, 2 disengagement keys and installation instructions)

Manufactured by the Portuguese company Electrocelos, known for the reliability and durability of its products. 

The LINCE 600 operator can move gate leaves with a width of up to 2.5m without an electric lock and with a width of 4.0m with the use of an electric lock.

The above kit can be installed for the automation of swing garage doors. Depending on your needs, products such as remote controls, photocells, etc. can be added to the kit.

 

LINCE 600 operator - Dimensions

dimensions of lince 600 operator

Operator with very convenient dimensions, suitable for most gates.

 

 Swing gate operator installation - Specifications

Installing a swing gate operator is relatively simple, as long as the necessary attention is paid to certain specific dimensions. These dimensions are as follows:

  • The width of the left and right gate leaves W& WR respectively.
  • The distances CL, DL & CR, DR. These dimensions are important when the operator is installed on the same side from which the gate opens. (Conversely, when the gate opens outwards and the operator is inside or vice versa, these dimensions do not play a role, but the clear passage width is reduced)
  • Maximum daily and hourly gate opening and closing cycles. 
  • The gate design. What we are interested in from the design is whether it allows air to pass through without resistance. That is, a barred gate is the best case, while a solid gate without gaps is certainly a gate that can face problems when strong winds prevail.

Our company is always ready to assist you in choosing the appropriate mechanism for your gate. You can contact us by phone or email and we will guide you in selecting the motor for your gate. It is essential to know the above information, and in case of sending an email, photos of the gate and the installation point of the mechanisms would facilitate our selection.

Analysis of critical dimensions for selecting a swing gate operator

WL, WR: width of each gate leaf

CL, CR: we open each leaf 90o and measure the distance perpendicular to the gate from a potential obstacle (structural element, tree, etc.) 

DL, DR: We measure perpendicular to the closed gate the distance from the point of installation of the operator's base to the point where the gate hinge is installed.

double swing gate spaces for motors

We measure the distances from the center of the hinge for greater accuracy:

swing operator distances from hinge

 

Visual inspections during swing gate operator installation

The first point of check during the installation of a swing gate operator is whether there is space for the arm. We open the gate 90o and observe if there is space behind it for the operator. If the gate abuts a structural element or other obstacle (like the right leaf in the diagram below) then an operator cannot be installed without modifying the gate or creating the appropriate space. (in this specific case, excavating the structural element and creating space for the motor)

inability to install swing arm on the right

Depending on the user's needs, the gate can be open-type or closed-type. Open-type gates allow visibility and air passage, as they are usually designed with bars. Conversely, closed-type gates do not allow visibility to and from the area and, of course, wind passage. This often makes movement difficult as wind pressure exerts great forces on the gate and consequently on the operator. Therefore, in areas where strong winds prevail, it is incorrect to install an operator on a solid swing gate. In the best case, the gate will not operate correctly (it will partially close) when there is wind pressure, and there are high chances of the operator being damaged. 

This point requires special attention as no manufacturer's warranty covers damages caused by wind pressure. In many cases, we could have better gate performance by installing a more powerful operator and/or an electric lock. In most cases, however, our advice is not to install a swing operator on a solid gate unless it is protected from strong wind pressure. (e.g., in densely populated areas, if there is a tall building in front, etc.) 

double swing gate wind pressure

Also, a basic prerequisite for installing an operator on a swing gate is that it operates perfectly manually and has mechanical stops.

Mechanical stops define the end of the gate's travel in both the open and closed positions.

Swing double leaf stops

 

 

Installation distances for swing operators - Operating modes

Swing operators can operate in 2 ways:

 1st way: They pull the gate to open it and push it to close it.

2nd way: They push the gate to open it and pull it to close it.

The following diagrams illustrate the operation of a swing gate. The gate rotates around an axis (H) which is defined by its hinges (from their center).

The motor is supported by 2 joints:

  1. The first is fixed and is the mounting point of the operator to the structural element. (P1)
  2. The second is movable and is the mounting point of the operator on the gate. (P2) 

These three points H, P1, P2 define a triangle with fixed sides H-P1 & H-P2 and one with variable length P1-P2. Depending on the installation method, the length P1-P2 increases when the gate opens and decreases when it closes, or vice versa.
The distance from the center of rotation of the operator to the center of rotation of the gate (H-P1) is what determines the operation of the operator. This is defined by the distances X and Y which are clearly distinguished in the next diagram. 

These distances are specified by the operator manufacturer and must be observed during installation. A detailed table with these distances follows below. 

Also, to determine point P2, we follow this procedure: In the first installation method, after defining point P1, we define point P2 at a distance Le where the piston is extended almost to the end of its stroke. In the second installation method, again after defining point P1, we define point P2 at a distance Lc where the piston is retracted almost to the limit of its stroke.

Detailed diagrams and tables follow, where S2 and S1 are the stops for the open and closed positions respectively.

1st way of installing a swing gate operator

right swing arm distances

 

 

lince 600 installation dimensions

This installation method is the most widespread and has the most advantages, as it does not alter the gate's design, the operators are inside the area and thus protected, and the clear opening width remains as it was before the operator's installation. The only disadvantage is that specific spaces are required for the operator's installation.  

 

2nd way of installing a swing gate operator

swing single leaf right swing arm

This installation method is rarely used. The motor is placed between the opening and pushes the gate to open it, while pulling it to close it. It offers advantages, the most significant of which is the possibility of installation even when the necessary spaces required for the first installation method are not available. Also, the mechanism does not alter the appearance of the gate and is inside, thus protected. Disadvantages of this method are that it reduces the clear passage width and that the gate opens outwards, which poses a risk to passers-by, etc. 

 

Double-leaf swing garage door - wiring

Wiring of double-leaf swing gate

  • (1) The operator requires a 4x1.5mm² or 4x2.5mm² cable if the installation point of the automation is far from the control panel. (it is advisable for the operator to be on a separate fuse in the control panel) The cable must be waterproof and in a conduit with a diameter of at least Φ16. The provision left by the electrician must be sufficient (1.5m) to reach the installation point of the electronic control panel.
  • (2) Wired photocells require a 4×0.6mm² cable for the receiver and a 2×0.6mm² cable for the transmitter. We usually place the receiver near the operator and the panel. If it is not possible to run a cable across for the photocells, we can install photocells with a reflector, which only require wiring on one side. (so line 2 is not required)
  • (4) For a button (or key button), a 2X0.5mm² cable is required (not included in the kit)
  • (5) The remote control receiver requires a 3X0.5mm² cable (in our case it is integrated into the panel)
  • (6) The safety light requires a 2X1.5mm² cable (not included in the kit)
  • (7) The electric lock requires a 2X1.5mm² cable (not included in the kit)

Remarks:

  • Single-leaf or double-leaf gate requires one control panel.
  • Heliflex type PVC flexible plastic pipes are most suitable for this type of installation.
  • Wiring must be protected and waterproof to prevent short circuits, etc.

ProfelmNet PSD-36T Swing Operator Remote Controls

 

Swing operator remote control

The ProfelmNet PSD-36T remote control features 4 buttons, allowing you to control 4 different mechanisms. It has a fixed 12-bit code at 433.92 MHz. It is user-friendly, well-designed, and works perfectly with swing operator control boards.

 

Wired photocells of the LINCE 600 kit (Kit-Standard-2114)

safety photocells

Safety photocells are a product that prevents accidents and damage at low cost. If there is an obstacle between the transmitter and the receiver, they prevent the door from closing, thereby protecting pedestrians, vehicles, etc. If it is not possible to run cables to the opposite side, photocells with a reflector can be installed at a small extra cost.

Lince 600 swing operator manual override

 Steps for manual override of the swing operator:

Unclip the protective cover:

lince 400 manual override protective cover

Check the special marking for the opening direction:

Lince 400 manual override marking

Insert the manual override key:

lince 400 disengagement key

Turn the key 180o as shown in the diagram below:

Lince 400 manual override procedure

The manual override procedure is complete. The gate can now be moved by hand. To restore the operator to electric operation, follow the reverse procedure. 

Lince 600 operator installation instructions

The kit comes with instructions in Greek which are easy to follow, provided one has basic knowledge and is "handy". Otherwise, it is advisable to call a specialized technician.

The instructions include detailed steps for the installation of the operator base, the operator itself, as well as all accessories that a swing kit may contain (photocells, remote controls, flashing light, antenna, etc.)

Instructions in English for the motor can be found at the following link: Lince 600 EN operator instructions